Wiki Page: BrowserNavigate(BrowserEngine: 32 - Internet Explorer request...
The Browser Driven Loadtesting feature utilizes components and settings of Internet Explorer on the machine from which it runs. Required proxy settings must be set within Internet Explorer's settings...
View ArticleWiki Page: An action triggered by pressing a modifier key is not triggered on...
By default the recorder records the high level function BrowserSetText to set the text value of a text control. BrowserSetText uses high level calls to the Browsers DOM API rather than sending actual...
View ArticleWiki Page: TM ART error: "Cannot get a connection, pool error. Could not...
When trying to create a database schema on an existing but empty SQL Server database, TM ART will show this error: "Cannot get a connection, pool error. Could not create a validated object, cause:...
View ArticleWiki Page: Recording rule to force the replacement of a form field value with...
There are circumstances where it may be useful to automatically replace form field values with a variable using a recording rule but no parse is involved. The following rule finds all form fields with...
View ArticleWiki Page: Proxy record an application that does not have proxy support
There may be occasions where it is necessary to proxy record an application but that application does not contain the ability to specify a proxy. It may be possible to record the traffic using the...
View ArticleWiki Page: No BDLT authentication function recorded for NTLM authenticated...
The authentication function (BrowserSetAuthentication) will only be recorded in BDLT scripts when a user is actually prompted for the credentials during login. It is possible however to force Internet...
View ArticleWiki Page: Why might my monitor remain in blackout after the end time is...
The behavior of Blackouts changed in TM ART 4.1. This change was implemented due to Daylight Saving Time (DST) changes made in TM ART 4.1. TM ART 4.1 help “Blackout Periods Page” incorrectly states:...
View ArticleWiki Page: Increase the retention period for the Audit Log
There may be a requirement to retain the Audit Log information beyond the default of 91 days. This retention period is configured in the SccAppServerBootConf.xml configuration file. The default...
View ArticleWiki Page: Error: LoadtestController: 3201 - License Error: Not all features...
When attempting to replay a script and the following error is reported: "Error: LoadtestController: 3201 - License Error: Not all features are available - execution is denied due to registration...
View ArticleWiki Page: Can I calculate the ApDex within SilkPerformer?
An automated means of determining the ApDex (Application Performance Index) calculation is not available within SilkPerformer, however it is possible to manually customize a solution within your...
View ArticleWiki Page: BrowserEngine: 13 - GetText failed
When using BrowserGetText() with a large amount of text, in certain circumstances, when the large data is not handled correctly, you will get a BrowserEngine: 13 error instead of the usual “RT: 70 -...
View ArticleWiki Page: Multiple instances of the "UNSUCCESSFULLY deleted result file"...
Result files that are sent from an Execution Server are temporarily stored on the Application Server until they are written to the database repository. After the database write has been committed...
View ArticleWiki Page: "SSL initialization runtime error" reported in the Application...
This applies to TM ART Central 4.1 When using the BMC TM ART 4.1 SSL Password Encrypter tool as part of the process to replace the security certificate for Execution Server and Application Server...
View ArticleWiki Page: Why might my warmup time appear to last longer than expected?
The current user status for each Virtual User can be seen in the Status column in the Monitor pane: If you see a situation where a user appears to remain in 'warmup' for longer than expected this can...
View ArticleWiki Page: RaiseError message parameter limitations
The Virtual User tab, or the Error tab, of the Output window may hang after running a test which makes use of the RaiseError function in SilkPerformer 2011. This issue is caused by specifying a...
View ArticleForum Post: Importing XMI file fails
I had tried to export/import a model from Sparx Enterprise Architect v10.0 into Together 12.6 using an XMI-file, but when trying to import the file into Together I only get the following error...
View ArticleForum Post: rm/cobol to visual cobol: application windows/dialogs using rmputil
i have a program written in rm/cobol that i am trying to compile using visual cobol. i am have set the proper dialect and its compiling successfully. the problem i am facing is on the windowing...
View ArticleForum Post: RE: .net SDK
community.microfocus.com/.../10739.aspx please review this announcement. the links to all sdk deliverables for the 13.0 & 14.0 versions of the product suite, spanning all supported (java &...
View ArticleForum Post: RE: deleting objects
Hi Fran, Please create a support incident for this problem and attach the screenset to the incident so that we can take a look. Thanks.
View Article